Description
Flame Failure Response Time (sec): 1.5 sec.
Ignition System Type: Direct Hot Surface Ignition
Ignition Sequence: The number of trials for ignition and trial time is determined by the dip switch selection.
Typical Gas Control: VR8205, VR8305
Flame Sense: Single Rod or Two Rods
Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270)
Ignition Trials To Lockout: 1 or 3
Lockout Timing: 4 sec. or 7 sec.
Ignition Trial Time (sec): 4 sec. or 7 sec.
Maximum Valve Load @ 24 Vac (Amps): 2A
Typical Ignition Hardware: Norton 201, Norton 271, Q354
Between Trial Time: (2) 96 sec (32 Seconds Prepurge and 64 seconds interpurge)
Overview
Universal hot surface ignition module replaces multiple field installed hot surface ignition modules supplied by Resideo, White-Rodgers, Robertshaw and Johnson. Uses a 120 VAC igniter. Includes cross reference, instructions, and accessories for easy replacement.
Features
• Replaces over 800 White-Rodgers, Robertshaw and Resideo hot surface ignition models.
• For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent).
• S8910U 3000 Series has LED status indicator and microammeter ports for easy trouble shooting
• For local (single rod) or remote (dual rod) rectification type flame sensing.
• Contains easy-to-use cross reference and instructions plus the accessories required to replace the existing hot surface ignition module.
• Provides one or three ignition trials (four-second or seven-second trials) per call for heat.
• Field selectable number of ignition trials and trial time based on unit being replaced.
• Igniter warm up time: 7 (12 seconds second and third trial), 17 (27 seconds second and third trial), 34, or 45 seconds
Ignition System Type: Direct Hot Surface Ignition
Ignition Sequence: The number of trials for ignition and trial time is determined by the dip switch selection.
Typical Gas Control: VR8205, VR8305
Flame Sense: Single Rod or Two Rods
Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270)
Ignition Trials To Lockout: 1 or 3
Lockout Timing: 4 sec. or 7 sec.
Ignition Trial Time (sec): 4 sec. or 7 sec.
Maximum Valve Load @ 24 Vac (Amps): 2A
Typical Ignition Hardware: Norton 201, Norton 271, Q354
Between Trial Time: (2) 96 sec (32 Seconds Prepurge and 64 seconds interpurge)
Overview
Universal hot surface ignition module replaces multiple field installed hot surface ignition modules supplied by Resideo, White-Rodgers, Robertshaw and Johnson. Uses a 120 VAC igniter. Includes cross reference, instructions, and accessories for easy replacement.
Features
• Replaces over 800 White-Rodgers, Robertshaw and Resideo hot surface ignition models.
• For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent).
• S8910U 3000 Series has LED status indicator and microammeter ports for easy trouble shooting
• For local (single rod) or remote (dual rod) rectification type flame sensing.
• Contains easy-to-use cross reference and instructions plus the accessories required to replace the existing hot surface ignition module.
• Provides one or three ignition trials (four-second or seven-second trials) per call for heat.
• Field selectable number of ignition trials and trial time based on unit being replaced.
• Igniter warm up time: 7 (12 seconds second and third trial), 17 (27 seconds second and third trial), 34, or 45 seconds